Cookie Img

Flow Meter

Flow Meter
Flow Meter
Product Code : FM - 98
Product Description

Flow Meter

Technical specifications:

Turbine Flow meter


Description

Type

A

Flow sensor pulse output three-wire system, +12V power supply


B

Local display , powered by 3.6V battery


C

Local display with 4~20mA ou pulse output,powered by24v.


D

Flow transmitter 4~20mA output,powered by 24V:


Nominal drift diameter

4




Normal flow range m3/hr

0.04~0.25

Extended flow range m3/hr

0.04~0.4

6




0.1~0.6

0.06~0.6

10




0.2~1.2

0.15~1.5

15




0.6~6

0.4~8

20




0.8~8

0.45~9

25




1~10

0.5~10

32




1.5~15

0.75~15

40




2~20

1~20

50




4~40

2~40

65




7~70

3.5~70

80




10~100

5~100

100




20~200

10~200

125




25~250

12.5~250

150




30~300

15~300

200




80~800

40~800

Explosion protection




Not marked, without explosion protection

B



Explosion protection type

Precision class


A


Precision : Class 0.5


B


Precision : Class 1.0

NOTE:-

  • Sensors with pipe diameter of DN4~DN40 are of thread connections with maximum operating pressure of 6.3 Mpa.

  • Sensors with pipe diameter of DN50~DN200 are of flange connections with maximum operating pressure of 2.5 Mpa.

  • Sensors with pipe diameter of DN4~DN10 are provided with front and rear straight pipe sections and filters.

  • Please specify whcn placing an order if flange connections are required for pipe diameter of DN15~DN40

  • Please specify when placing an order for high pressure type and special requirements.


Flow Meter

Technical specifications:

Turbine Flow meter


Description

Type

A

Flow sensor pulse output three-wire system, +12V power supply


B

Local display , powered by 3.6V battery


C

Local display with 4~20mA ou pulse output,powered by24v.


D

Flow transmitter 4~20mA output,powered by 24V:


Nominal drift diameter

4




Normal flow range m3/hr

0.04~0.25

Extended flow range m3/hr

0.04~0.4

6




0.1~0.6

0.06~0.6

10




0.2~1.2

0.15~1.5

15




0.6~6

0.4~8

20




0.8~8

0.45~9

25




1~10

0.5~10

32




1.5~15

0.75~15

40




2~20

1~20

50




4~40

2~40

65




7~70

3.5~70

80




10~100

5~100

100




20~200

10~200

125




25~250

12.5~250

150




30~300

15~300

200




80~800

40~800

Explosion protection




Not marked, without explosion protection

B



Explosion protection type

Precision class


A


Precision : Class 0.5


B


Precision : Class 1.0

NOTE:-

  • Sensors with pipe diameter of DN4~DN40 are of thread connections with maximum operating pressure of 6.3 Mpa.

  • Sensors with pipe diameter of DN50~DN200 are of flange connections with maximum operating pressure of 2.5 Mpa.

  • Sensors with pipe diameter of DN4~DN10 are provided with front and rear straight pipe sections and filters.

  • Please specify whcn placing an order if flange connections are required for pipe diameter of DN15~DN40

  • Please specify when placing an order for high pressure type and special requirements.


Contact Us

1st Floor, Above Bhairavnath Post Office, Opp. Pragati Society, Nr Meera Cross Roads, Maninagar, Ahmedabad, Gujarat, 380028, India